国产亚洲欧美精品一区_国产手机在线无码播放视频_97精品人人妻人人_亚洲人成人无码网WWW电影首页

上海銳譽實業(yè)有限公司

SICK西克

i10-E0233 Lock
上海銳譽訂購

i10-E0233 Lock

型 號:i10-E0233
品 牌:SICK西克
價格-貨期:請咨詢我司商務(wù)
電 話:021-50189957
郵箱:??rymro@sina.com
i10-E0233產(chǎn)品詳細(xì)信息:

SICK西克i10-E0233 Lock價格優(yōu)惠了,上海銳譽為你提供更多SICK產(chǎn)品,期待你的咨詢。


Electro-mechanical safety switches
Safety locking devices, i10 Lock

Type i10-E0233 Lock
Part No. 6022585


At a glance
Narrow plastic housing
Rigid or mobile actuators
Available with M20 X 1.5 cable entry glands or Flexi Loop-compatible M12 plug connector (depending on variant)
Locked by spring force and magnetic force
Lock and door monitoring
IP 67 enclosure rating

Your benefits
Small design simplifies installation and makes it easy to mount directly on the guard door frame
Flexible electrical connectivity due to three cable entry glands
Improved diagnostics due to additional signaling contacts
Practical, simple adjustment due to various actuators that are suitable for any door
Different switching elements offer the appropriate solution for electrical installation
Flexi Loop now enables a safe series connection with enhanced diagnostics capabilities and minimal wiring effort.

Note: The actuator has to be ordered separately. See "Accessories" for further details.





Technical data
Housing material: Glass-fiber reinforced thermoplastic
Enclosure rating: IP 67 (IEC 60529)
Ambient operating temperature: -20 °C ... +55 °C
B10d parameter: 3*1E 06 switching cycles, with small load
Type: Type 2 (EN ISO 14119)
Actuator coding level: Low-level coding (EN ISO 14119)
Locking type: Electrical
Maximum locking force: 1,300 N
Number of actuation directions: 5
Approach speed: 20 m/min
Actuation force: 10 N
Switching principle: Slow action switching element
Number of positive action N/C solenoid monitoring contacts: 2
Number of N/O solenoid monitoring contacts: 1
Number of positive action N/C door monitoring contacts: 0
Number of N/O door monitoring contacts: 0
Number of N/C door monitoring contacts: 1
Mechanical life: 1* 1E 06 switching cycles
Usage category: AC-15/DC-13 (IEC 60947-5-1)
Rated operating current (voltage): 4 A (230 V AC)
4 A (24 V DC)
Solenoid operating voltage: 24 V DC
Connection type: Cable gland, 3 x M20
Flexi Loop-compatible plug connector: -
For process protection only: -
Weight: 0.46 kg